8/10/2010 · A bigger escalator that runs all day and all night in a convention center or hotelsay, a 20-foot-high unit with a 20-horsepower motor would use roughly 31,000 kWh annually.
2/1/1999 · This paper outlines the method of calculating the necessary size of motor needed to drive a lift or an escalator . To calculate the size of a motor .
UNIVERSAL ESCALATOR MOTOR Model YFT160 AUTOMATIC ESCALATOR MOTOR The YFT160 universal escalator motor is designed speci? cally for modern, auto-matic escalators . The motor is factory equipped with a spring-applied, electrically … The motor is available in 7.5 kW and 11 kW power output ratings (16.2 and and 23A respectively).
Rated for 30 starts per hour 7.5 and 11 kW power ratings Voltages: 200, 208, 220, 230, 380 – 400, 415, 440, 460, 480, 500 VAC 3-phase, 50/60 Hz YFT160 motors are designed to meet the reversing and starting requirements of modern escalators as well as those of a traditional continuous operating environment Insulation Class F, VDE …
Figure 1 shows the energy-saving benefits of using a reduced-speed mode in an escalator application featuring a 15kW induction motor in various control modes. The largest incremental savings result from using a VFD to operate the motor at a reduced speed during periods of inactivity. Figure 1: Power Consumption ( kW ) of unloaded 15kW Escalator Motor, P : power of motor kW . ST : daily running with people. TP: travel time. Example: Motor power 2.8 kW , speed of the elevator 1m / s, running daily start 100, TP (door open + door close + departure + arrival + time to travel + arrival + door open +door close) is 12 seconds for 360 days. Einv = 0.3 x 2.8 x 100 x 12/3600 = 0.28 kWh / day, LIFT AND ESCALATOR MOTOR SIZING WITH CALCULATIONS & EXAMPLES . Dr. Lutfi Al-Sharif . Published in Lift Report, January/February 1999. … Thus, a 50 kW motor .
8 Schindler Escalators Schindler 9300AE 9 Superb performance, global service The Schindler 9300AE escalator is a product with superb quality and performance, thanks to its high-grade, low-wear-and-tear components.
Assume Escalator A is a mid-high-traffic escalator equipped with a 30- kW motor . From Figure 1s active power analysis graph, we discover something applicable, in general, for escalators and moving walks: ? Motors will work during traffic peaks at 30-50% of their rated.
B4.2 Motor Efficiency . B4.3 Service-on-demand Escalator /Passenger Conveyor Control . SECTION B5 REQUIREMENTS FOR LIFT RIDE QUALITY . B5.1 General . B5.2 Lateral and Vertical Vibration . B5.3 Noise Level . B5.4 Acceleration and Deceleration . B5.5 Jerk